SM303-HRS TE cooled Back-Thinned 1024 px array CCD spectrometer
- - High Resolution optical bench
- - Scientific-grade high performance
- - Extremely low dark noise and stray light
- - Wide Dynamic range and high signal to noise ratio
- - High Ultra-Violet Quantum efficiency
- - Flexible optical input direct to slit or via fiber
- - Designed from the ground up for a wide range of applications
- - High speed data acquisition
- - Standard design allows up to 200 to 1050nm range
The SM303 is ideal for UV/VIS/NIR spectrometry that requires a very high signal-to-noise ratio and/or high dynamic range, like fluorescence, Raman, and LED property testing applications. The back-thinned CCD has excellent sensitivity to UV and allows deep UV application. Well-designed housing allows up to 75nm measurement window within 200~1050nm for 0.2nm optical resolution with very low stray light. The TE cooled detector also helps to measure very low light signals by reducing the noise level over a long integration time.
NOTE: Please click SM303-HRS for the brochure file.
To contact us for more information, please click the "Contact Us" button to go to the Contact Us page. To request a quote or more details about this item, please click the "Email Inquiry" button to open an email to us.
Software
- SM32Pro & SMProMX - Windows (32-bit/64-bit) based software for data acquisition and analysis
- Transmission, reflectance, and absorbance measurements
- Data export, zoom in and out, spectrum overlays, and many more features
- Color analysis tools included
- Signal average and integration time control
- DLL libraries available for easy user software development
- VC++ / VB / LabView / Matlab examples available
Model |
SM303 HRS |
Detector |
Hamamatsu S7031-1006 Back-Thinned CCD
|
Spectral Resolution |
0.2 - 7nm FWHM |
Spectral Range |
Full Range: 200 - 1050nm |
Spectrograph f# |
3.3 |
Fiber Coupler |
SMA905 or FC standard |
Stray Light |
< 0.01% @632nm (< 0.05% avg) |
Dark Noise RMS |
< 2 RMS counts @35ms |
Signal to Noise Ratio |
1000 : 1 |
min. Integration Time |
7ms |
Trigger mode |
Free Run mode |
Orders Sorting Filter |
Longpass filter or linear variable filter installed per wavelength coverage |
Computer Interface |
USB 1.1 / 2.0 compatible |
SDK Support |
Visual C++, Visual Basic, LabView, Matlab |
Dimensions |
9.25 x 6.95 x 3.75 inches (23.5 x 17.65 x 9.52cm) |
Weight |
8.16 lbs (3.7 kg) |
Slit Options |
10, 25, 50, 100, 200, and 400µm |
TE Cooling Temperature |
-10°C (one stage TE cooling) |