SM642-HRS High Resolution Spectrometer
- High Resolution optical bench
- Scientific-grade high performance with low cost
- Low dark noise and stray light
- Good dynamic range and high signal to noise ratio
- High Ultraviolet Quantum efficiency
- Flexible optical input direct to slit or via fiber
- Designed from the ground up for a wide range of applications
- High speed data acquisition
- Standard design allows up to 200 - 1050nm range
Spectral Products is offering the new SM642 non-TE cooled Back-Thinned 2048pixel array CCD spectrometer. The SM642 provides high quantum efficiency in UV and high dynamic range. The detector used in the SM642 HRS has 2048 pixels and helps to get a better resolution. It is ideal for UV/VIS/NIR spectrometry that requires a high signal-to-noise ratio and/or high dynamic range. The back-thinned CCD has excellent sensitivity to UV and allows deep UV application, even below 200nm. Well-designed housing allows up to 75nm measurement window within 200~1050nm for 0.2nm optical resolution with very low stray light. The Back-Thinned detector measures very low light signals by reducing the noise level over a long integration time.
NOTE: Please click SM642-HRS for the brochure file.
To contact us for more information, please click the "Contact Us" button to go to the Contact Us page. To request a quote or more details about this item, please click the "Email Inquiry" button to open an email to us.
Software
- SM32Pro & SMProMX - Windows (32-bit/64-bit) based software for data acquisition and analysis
- Transmission, reflectance, and absorbance measurements
- Data export, zoom in and out, spectrum overlays, and many more features
- Color analysis tools included
- Signal average and integration time control
- DLL libraries available for easy user software development
- VC++ / VB / LabView / Matlab examples available
Model |
SM642 HRS |
Detector |
Hamamatsu S10420-1106 non-TE-cooled Back-Thinned CCD
|
Spectral Resolution |
0.1 - 7.0nm FWHM |
Spectral Range |
Full Range: 200 - 1050nm UV Range: 200 - 450nm VIS Range: 380 - 760nm NIR Range: 550 - 1050nm |
Spectrograph f# |
3.3 |
Fiber Coupler |
SMA 905 or FC standard |
Stray Light |
< 0.01% @632nm (< 0.5% avg) |
Dark Noise RMS |
< 7 RMS counts @35ms |
Signal to Noise Ratio |
450 : 1 |
min. Integration time |
7ms |
Trigger mode |
Free Run mode |
Orders Sorting Filter |
Longpass filter or linear variable filter installed per wavelength coverage |
Computer Interface |
USB 1.1 / 2.0 compatible |
SDK Support |
Visual C++, Visual Basic, LabView, Matlab |
Dimensions |
8.66 x 6.89 x 3.36 inches (22.0 x 17.5 x 8.55 cm) |
Weight |
6.61 lbs (3.0 kg) |
Slit Options |
10, 25, 50, 100, 200, and 400µm |
Temperature Induced Shift |
±1 pixels per ±15°C |