Cookie Consent by Free Privacy Policy Generator Update cookies preferences

Skip to menu

XEDITION

SM242/SM442 Preconfigured CCD Spectrometer

The Choice for Spectral Applications

 


- New compact, pre-configured model
- Can be handheld or securely mounted
- Flexible optical input direct to slit or via fiber
- Designed from the ground up for a wide range of applications
- Impact resistant housing
- High-performance electronics
- Standard design allows up to 200 - 1050nm range
- Support up to 8 USB multi-channel configuration
UV enhancing coating (option)

 

 

The SM242/SM442 is a new compact design CCD Spectrometer for use with a PC. Based on SP's special optical bench design, it supports many different applications where spectral or color measurements are required, including high dynamic range applications. The SM242/SM442 can accept light directly through its built-in slit or via optical fiber. The durable aluminum housing that encloses the SM242/SM442 provides stable optical bench operation over a wide range of temperatures. The standard sensor arrays used are the Sony ILX 511 for SM242 and the Toshiba TCD1304 for SM442. The array driver electronics have been designed for highly sensitive yet stable operation. This array (in conjunction with our special UV coating process and customized order sorting filters) allows up to an 850nm measurement window from 200nm to 1050nm (smaller measurement window sizes increase spectral resolution and light sensitivity). Thanks to the more pixel numbers, the SM442 is preferable for applications requiring higher resolution. The better sensitivity of the CCD makes the SM242 more suitable for applications with lower light signals. The standard interface to the SM242/SM442 is a USB 1.1/2.0 compatible interface with a 16-bit extended dynamic range. Our USB board can support multichannel configurations up to 8. With this multichannel configuration, a higher resolution for a wide range or a dual spectrometer system (one for measurement and the other for reference) is possible. Spectral Products applies a new UV enhancing coating on the CCD to increase the UV sensitivity below 450nm compared with the conventional UV coating that is widely used in CCD spectrometers. With the help of this new UV coating, the signal sensitivity below 500nm can get improved by ~20-50% more in general. The SM242/SM442 is a pre-configured model so if the desired wavelength range matches one of the standard wavelength ranges, SP can ship the unit within a couple of days.

Software support includes an SDK and DLLs for dedicated applications development and our SM32Pro Windows-based spectral acquisition and analysis software.

 

To contact us for more information, please click the "Contact Us" button to go to the Contact Us page. To request a quote or more details about this item, please click the "Email Inquiry" button to open an email to us. 

 

Contact Us      Email Inquiry

 


Model

SM242

SM442

Detector SONY ILX 511
Pixels: 2048
Sensing Pixel Size: 14um x 200um
Sensitivity: 200V (lx s) under 3200K uniform illumination
Toshiba TCD 1304
Pixels: 3648
Sensing Pixel Size: 8um x 200um
Sensitivity: 160V (lx s) under daylight fluorescent illumination
Spectral Resolution 0.15 to 10nm depending on the slit and grating choices
Spectral Range 200 - 1050nm
Spectrograph f# 2.7
Fiber Coupler SMA 905 or FC standard
Stray Light < 0.05% @632nm (< 0.1% overall)
Slit Options 5, 10, 25, 50, 100, 200, 400um
Orders Sorting Filter Longpass filter or linear variable filter installed per wavelength coverage
Computer Interface USB 1.1 / 2.0 16-bit (support up to 8 multi-channel configuration)
Software

Windows 98/Me/2000/XP/VISTA/Win7/Win8.1/Win10 (both 32/64bit)

SM32Pro & SMProMX (free with spectrometer)
Includes DLL libraries and SDKs for easy custom application development

Dimensions 3.82H x 2.6W x 1.85D inches
Weight 0.9lbs
min. Integration Time 1ms 8ms
Dark Noise RMS < 50 RMS counts in 16bit @ 35msec integration time
Signal to Noise ratio 250 : 1
Trigger mode Free Run Mode
External Trigger Mode
Up